1.Quick Troubleshooting

ProblemQuick Fix
Device not turning ONCharge fully and switch the Power Switch ON.
Gear button not workingMake sure the Power Switch is ON first.
Low suctionClean the dust bin, HEPA filter and air path.
Low blower speedCheck the blower nozzle and clear any blockage.
Device stops during useCheck battery level and nozzle blockage.
No charging indicatorCheck the Type-C cable and power adapter connection.
Filter needs cleaningRemove, wash, dry completely and reinstall.
Device shuts off after blockageWait 30 seconds, clear the blockage and restart.
Cannot use while chargingThis is normal; the manual states the device cannot be used while charging.

2. Device Not Turning ON

  1. Confirm the Power Switch is in the ON position.

  2. Charge the device fully.

  3. Check the battery indicator.

  4. Try switching it ON again.

3. Gear Button Not Responding

The Gear button controls the three speed levels only when the main Power Switch is ON.

Try:

  1. Slide the Power Switch to ON.

  2. Press Gear once for Speed 1.

  3. Press again for Speed 2.

  4. Press again for Speed 3.

4. Low Vacuum Suction

  1. Empty the dust bin.

  2. Remove and clean the HEPA filter and metal mesh.

  3. Check the nozzle and air path for blockage.

  4. Reassemble the filter correctly.

  5. Test again.

5.Suction Reference

SpeedApprox. Suction
14.2 kPa
27.2 kPa
319 kPa

6. Blower Performance Is Low

  1. Confirm the correct blower nozzle is attached to the back side.

  2. Check for blockage at the air outlet.

  3. Select a higher speed if required.

  4. Test again after cleaning the airflow path.

7.Blower Reference

SpeedApprox. Air Speed
129,000 RPM
243,500 RPM
387,000 RPM

8. Device Stops During Use

Possible causes include:

  • Low battery.

  • Blocked nozzle or airflow path.

  • Protection against overheating.

If the nozzle is blocked, the device may shut off automatically. Wait 30 seconds, clear the blockage and restart.

9. No Charging Indicator

  1. Check that the Type-C cable is connected correctly.

  2. Check the power adapter.

  3. Try charging again.

  4. The battery bars should illuminate progressively during charging.

10. Filter / Dust Bin Cleaning

Wash the HEPA filter and dust bin with water, then allow them to dry completely before reassembly.

Do not operate the device with wet filter components.

11. Unusual Noise, Smell or Overheating

Stop using the device immediately.

Do not open or repair it yourself. Contact support if the issue continues.

12. Important Safety Checks

Do not block the air inlet or outlet. Do not use the product near water, heat sources or flammable substances.

13.Before Raising a Support Request

InformationDetails
ProductMopcop X
Product CodePOR 3660
ModeVacuum / Blower
Speed1 / 2 / 3
Battery StatusIndicator level
Nozzle UsedVacuum / Blower nozzle
Filter StatusClean / Blocked / Wet
Exact SymptomCustomer description
Photo / VideoWhere relevant

14.Still stuck?

If the issue persists after performing all troubleshooting steps, please raise a support request.

Our support team will assist you further.

Support

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article