TABLE OF CONTENTS
- Quick Troubleshooting
- 1. Device Does Not Turn ON
- 2. No Indicator Light While Charging
- 3. Understanding the Indicator Lights
- 4. Airflow Is Weak in Blower Mode
- 5. Suction Is Weak in Vacuum Mode
- 6. Device Shuts OFF During Operation
- 7. Vacuum and Blower Modes Do Not Work Together
- 8. Device Does Not Operate While Charging
- 9. Cleaning the Nozzles and Air Openings
- 10. Cleaning the HEPA Filter
- Important Safety Reminders
- Still stuck?
Quick Troubleshooting
| Issue | Possible Cause | What to Do |
|---|---|---|
| Device does not turn ON | Battery may be low | Charge the device fully and try again |
| No indicator light while charging | Adapter or Type-C cable is not connected correctly | Check the adapter, power source and cable connection |
| Green indicator blinks | Low battery | Recharge the device |
| Airflow or suction is weak | Nozzle or air opening may be blocked | Switch OFF and clear the blockage |
| Device shuts off while operating | Nozzle blockage may have triggered protection | Wait 30 seconds, clear the blockage and restart |
| Device does not work while charging | Normal operating restriction | Disconnect the charger before using the device |
1. Device Does Not Turn ON
- Check whether the battery is low.
- Connect the supplied Type-C cable to the device.
- Use a compatible 5V/2A power source.
- Check that the cable is securely connected to the charging port.
- Observe the indicator light while charging.
- After charging, disconnect the cable and press the Power Button to switch ON the device.
The AirCop cannot be operated while it is charging.
2. No Indicator Light While Charging
- Check that the power adapter is connected properly to the power source.
- Check that the Type-C cable is securely connected to the AirCop.
- Use a compatible 5V/2A power source.
- Inspect the cable and adapter for visible damage.
- Try a working power outlet.
Do not use a damaged cable or unsuitable power adapter.
3. Understanding the Indicator Lights
| Indicator Light | Meaning |
|---|---|
| Green — Solid | Device in use |
| Red — Blinking | Charging |
| Red — Solid | Fully charged |
| Green — Blinking | Low battery |
If the green light blinks, recharge the device before continuing.
4. Airflow Is Weak in Blower Mode
- Switch OFF the AirCop.
- Check whether the blower nozzle is blocked by dust or debris.
- Remove the nozzle and clear the blockage.
- Check that the air inlet and outlet are not obstructed.
- Refit the nozzle securely.
- Restart blower mode and select the required speed.
The blower has 3 speed levels. Short-press the Blower Button to cycle through them.
5. Suction Is Weak in Vacuum Mode
- Switch OFF the device.
- Check the vacuum nozzle for dust or debris.
- Remove and clean the nozzle.
- Check the HEPA filter and clear accumulated dust.
- If the filter needs washing, allow it to dry completely before reinstalling it.
- Check that the air inlet and outlet are clear.
- Refit the nozzle and restart vacuum mode.
The vacuum function has 2 speed levels. Short-press the Vacuum Button to switch between them.
6. Device Shuts OFF During Operation
A blocked nozzle may cause the device to shut off automatically to help prevent overheating.
- Switch OFF the device.
- Wait 30 seconds.
- Remove the nozzle and clear the blockage.
- Check the air inlet and outlet for obstructions.
- Refit the nozzle securely.
- Restart the device.
If the device continues to shut off after the blockage has been cleared, stop using it and contact support.
7. Vacuum and Blower Modes Do Not Work Together
This is normal. The vacuum and blower functions cannot operate at the same time.
- Stop the currently active function.
- Press the button for the other function.
- Select the required speed.
8. Device Does Not Operate While Charging
This is a normal operating restriction. The device cannot be used while charging.
- Switch OFF the device.
- Disconnect the Type-C charging cable.
- Press the Power Button to switch ON the device.
- Select blower or vacuum mode.
9. Cleaning the Nozzles and Air Openings
- Switch OFF the device.
- Remove the nozzle attachment.
- Clear dust and debris from the nozzle.
- Check the air inlet and outlet.
- Wipe the device body using a soft, dry cloth.
- Refit the nozzle securely.
Do not use water, alcohol or chemical cleaners on the device body. Do not scratch the air vents with sharp objects.
10. Cleaning the HEPA Filter
- Switch OFF the device.
- Remove the HEPA filter.
- Clear accumulated dust.
- The HEPA filter is washable; rinse it separately as needed.
- Allow the filter to dry completely before reinstalling it.
- Do not operate the vacuum with a wet filter.
Important Safety Reminders
- Do not use the AirCop with wet hands or near water.
- Do not block the air inlet or outlet.
- Do not insert objects into the air openings.
- Keep away from heat sources and flammable substances.
- Stop using the device if it makes unusual noise, produces an unusual smell or overheats.
- Do not open or disassemble the product.
- Do not operate the device while charging.
- Do not use vacuum and blower modes simultaneously.
Still stuck?
If the issue persists after performing all troubleshooting steps, please raise a support request.
Our support team will assist you further.
Support
- Visit: www.portronics.com
- Support Portal: support.portronics.com